Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
2.
Blood Transfus ; 22(2): 150-156, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37458722

RESUMEN

BACKGROUND: Extracorporeal photopheresis (ECP) is a well-established but lengthy and burdensome cell-based therapy for various diseases such as cutaneous T-cell lymphoma, graft-versus-host disease and organ rejection after transplantation. The number of mononuclear cells (MNCs) that needs to be collected to obtain a clinical response to ECP is still under debate. The purpose of this retrospective study was to determine the number of lymphocytes, monocytes and neutrophils in mononuclear cell products (MCP) by flow cytometry and the collection efficiency in the offline ECP setting. MATERIALS AND METHODS: We collected data from 10 different patients undergoing 162 ECP procedures using the Spectra Optia device for MNC collection. White blood cell (WBC) count of MCP was determined using a hematology analyzer. MNCs were analyzed for CD45 and CD14 expression by flow cytometry to exactly determine the collected lymphocyte and monocyte fractions. RESULTS: Collected MCP showed high cell yields with 55.3×106/kg MNCs and 41.1×106/kg lymphocytes. MCP were characterized by high MNC (81.3%) and low neutrophils (18.7%) percentage. Mean collection efficiency for WBCs and for MNCs was 23.9% and 62.0%, respectively. The MNC fraction showed a moderate to high correlation between peripheral blood cell count of patients and MCP count. DISCUSSION: This study is one of a few reports showing the monocyte-to-lymphocyte relation in MCP for ECP determined by flow cytometry. In comparison to historical data from inline ECP, the offline ECP processing one total blood volume results in considerably higher cell yields. For this reason, and to reduce the burden on patients, we propose that the offline ECP processing time can be substantially reduced.


Asunto(s)
Enfermedad Injerto contra Huésped , Fotoféresis , Humanos , Fotoféresis/métodos , Leucocitos Mononucleares , Estudios Retrospectivos , Linfocitos , Recuento de Leucocitos , Enfermedad Injerto contra Huésped/terapia
3.
Arch Pathol Lab Med ; 147(1): 117-124, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-35472855

RESUMEN

CONTEXT.­: Underuse of laboratory testing has been previously investigated in preselected populations, such as documented malpractice claims. However, these numbers might not reflect real-life situations. OBJECTIVE.­: To evaluate the underuse and misuse of laboratory follow-up testing in a real-life hospital patient population with microcytic anemia, using laboratory results ordered during routine patient care. DESIGN.­: From all patients in whom a microcytic anemia was detected during routine diagnostics in 2018, all available laboratory data were collected and screened for appropriateness of diagnostic workup of iron deficiency and thalassemia. Subgroup analysis was performed for patient groups with mean corpuscular volume values 75 to 79 µm3 (group 1), 65 to 74 µm3 (group 2), and <65 µm3 (group 3). RESULTS.­: A total of 2244 patients with microcytic anemia were identified. Follow-up testing for iron deficiency was not performed in 761 cases (34%). For inconclusive ferritin levels due to elevated C-reactive protein results (n = 336), reticulocyte hemoglobin content or soluble transferrin receptor levels were missing in 86 cases (26%). In patients with suspected thalassemia (n = 127), follow-up testing for hemoglobin variants was not performed in 70 cases (55%). Subgroup analysis showed that the frequency of underuse of iron status as well as thalassemia/hemoglobinopathy testing decreased from group 1 to group 3. When considering relevant preexisting anemia diagnoses, laboratory tests were underused in 904 cases (40.3%). CONCLUSIONS.­: Because 40% (n = 904) of the patients with microcytic anemia were potentially not followed up correctly, laboratory specialists are advised to act by implementing demand management strategies in collaboration with clinicians to overcome underuse of laboratory tests and to improve patient safety.


Asunto(s)
Anemia Ferropénica , Talasemia , Humanos , Anemia Ferropénica/diagnóstico , Talasemia/diagnóstico , Hierro , Hemoglobinas/análisis , Hospitales
4.
Clin Chem Lab Med ; 60(9): 1356-1364, 2022 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-35696446

RESUMEN

OBJECTIVES: Although laboratory result presentation may lead to information overload and subsequent missed or delayed diagnosis, little has been done in the past to improve this post-analytical issue. We aimed to investigate the efficiency, efficacy and user satisfaction of alternative report formats. METHODS: We redesigned cumulative (sparkline format) and single reports (improved tabular and z-log format) and tested these on 46 physicians, nurses and medical students in comparison to the classical tabular formats, by asking standardized questions on general items on the reports as well as on suspected diagnosis and follow-up treatment or diagnostics. RESULTS: Efficacy remained at a very high level both in the new formats as well as in the classical formats. We found no significant difference in any of the groups. Efficiency improved in all groups when using the sparkline cumulative format and marginally when showing the improved tabular format. When asking medical questions, efficiency and efficacy remained similar between report formats and groups. All alternative reports were subjectively more attractive to the majority of participants. CONCLUSIONS: Showing cumulative reports as a graphical display led to faster detection of general information on the report with the same level of correctness. Considering the familiarity bias of the classical single report formats, the borderline-significant improvement of the alternative tabular format and the non-inferiority of the z-log format, suggests that single reports might benefit from some improvements derived from basic information design.


Asunto(s)
Química Clínica , Satisfacción Personal , Humanos , Laboratorios , Informe de Investigación
5.
Clin Chim Acta ; 532: 1-9, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35597305

RESUMEN

BACKGROUND: Recommendations on the optimal preservation of 24 h urine for the metabolic work-up in urolithiasis patients are very heterogeneous. In case two such tests with different storage condition recommendations are being analysed, multiple collections would be needed, challenging especially elderly and very young patients. We therefore aimed to evaluate the stability of urine constituents under different storage conditions. MATERIAL AND METHODS: We collected urine samples from ten healthy volunteers and prepared aliquots to be stored either at room temperature or 4 °C. Some aliquots were preserved using hydrochloric acid prior to storage, some thereafter, some using the BD Urine preservation tube and some were not preserved at all. Storage duration was 0, 24, 48 or 72 h. In all samples calcium, magnesium, phosphorus, creatinine, oxalate, citrate and uric acid were measured and compared to the according reference sample. RESULTS: We could not find any significant deviation for any of the analytes and preanalytical treatment conditions compared to the associated reference sample. CONCLUSION: Preservation of 24 h urine for the metabolic evaluation in stone formers might not be necessary for sample storage up to 72 h.


Asunto(s)
Urolitiasis , Anciano , Calcio , Ácido Cítrico , Humanos , Concentración de Iones de Hidrógeno , Magnesio , Factores de Riesgo , Urolitiasis/diagnóstico , Urolitiasis/orina
6.
Ther Adv Neurol Disord ; 15: 17562864221092092, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35479655

RESUMEN

Background: Anti-CD20 therapies induce pronounced B-cell depletion and blunt humoral responses to vaccines. Recovery kinetics of anti-CD20 therapy-mediated cellular and humoral effects in people with multiple sclerosis (pwMS) are poorly defined. Objective: To investigate the duration of the anti-CD20 treatment-induced effects on humoral responses to COVID-19 vaccines. Methods: This retrospective observational study included pwMS who had discontinued anti-CD20 therapy for ⩾12 months and remained without immunomodulation. We retrieved demographics and laboratory parameters including B-cell counts and immunoglobulin (IgG, IgM, IgA) levels prior to anti-CD20 commencement (baseline) and longitudinally after anti-CD20 treatment discontinuation from electronic medical records. Humoral responses to SARS-CoV-2 vaccines were compared with a population of 11 pwMS with ongoing anti-CD20 medication (control cohort). Results: A total of 24 pwMS had discontinued anti-CD20 therapy for a median of 34 months (range: 16-38 months). Antibody responses to COVID-19 vaccines were available in 17 (71%). Most individuals (n = 15, 88%) elicited a measurable antibody response [mean: 774 BAU/ml (±SD 1283 BAU/ml)] to SARS-CoV-2 immunization on average 22 months (range: 10-30 months) from the last anti-CD20 infusion, which was higher compared with the population with ongoing anti-CD20 therapy (n = 11, mean: 12.36 ± SD 11.94 BAU/ml; p < 0.00001). Significantly increased antibody levels compared with the control cohort were found among pwMS who were vaccinated >18 months after treatment discontinuation (19-24 months: n = 2, p = 0.013; 25-36 months: n = 9; p < 0.001). The interindividual kinetics for B-cell reconstitution were heterogeneous and mean B-cell counts approached normal ranges 18 months after treatment discontinuation. There was no correlation of B-cell repopulation and vaccine responses. Mean total IgG, IgM, and IgA levels remained within the reference range. Conclusion: Anti-CD20-induced inhibition of humoral responses to COVID-19 vaccines is transient and antibody production was more pronounced >18 months after anti-CD20 treatment discontinuation. The immunological effect on B-cell counts appears to wane by the same time.

7.
Diagnostics (Basel) ; 11(7)2021 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-34201549

RESUMEN

Inappropriate laboratory test selection in the form of overutilization as well as underutilization frequently occurs despite available guidelines. There is broad approval among laboratory specialists as well as clinicians that demand management strategies are useful tools to avoid this issue. Most of these tools are based on automated algorithms or other types of machine learning. This review summarizes the available demand management strategies that may be adopted to local settings. We believe that artificial intelligence may help to further improve these available tools.

9.
Biochem Med (Zagreb) ; 30(2): 020502, 2020 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-32550813

RESUMEN

Laboratory analyses are crucial for diagnosis, follow-up and treatment decisions. Since mistakes in every step of the total testing process may potentially affect patient safety, a broad knowledge and systematic assessment of laboratory errors is essential for future improvement. In this review, we aim to discuss the types and frequencies of potential errors in the total testing process, quality management options, as well as tentative solutions for improvement. Unlike most currently available reviews on this topic, we also include errors in test-selection, reporting and interpretation/action of test results. We believe that laboratory specialists will need to refocus on many process steps belonging to the extra-analytical phases, intensifying collaborations with clinicians and supporting test selection and interpretation. This would hopefully lead to substantial improvements in these activities, but may also bring more value to the role of laboratory specialists within the health care setting.


Asunto(s)
Toma de Decisiones Clínicas , Técnicas de Laboratorio Clínico/normas , Errores Médicos/prevención & control , Flebotomía/normas , Centrifugación , Europa (Continente) , Humanos , Uso Excesivo de los Servicios de Salud , Seguridad del Paciente , Control de Calidad , Indicadores de Calidad de la Atención de Salud , Valores de Referencia , Reproducibilidad de los Resultados
10.
Clin Biochem ; 80: 14-18, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32229197

RESUMEN

INTRODUCTION: Too frequent HbA1c measurements may lead to unnecessary treatment modifications of diabetic patients. The aim of this study was to estimate the percentage of falsely elevated HbA1c results in two hospitals, Landeskrankenhaus/Uniklinikum Salzburg (LKH) and Landesklinik St. Veit (STV), as well as to retrospectively investigate the effect of an automated and an educative 60-day re-testing interval (RTI). METHODS: The amount of estimated falsely elevated results (eFER), based on odds calculated using the baseline and the follow-up values and the time between these measurements, the number of HbA1c re-testings within 60 days as well as the overall number of ordered and performed HbA1c analyses were calculated. In LKH, an automated algorithm cancelling inappropriate HbA1c testing was applied, and in STV, educational actions were taken. RESULTS: Before RTI-implementation, eFER were 0.9% and 2.1% and within-60-days-re-testing were 15.0% and 7.4% of cases in LKH and STV, respectively. After RTI-implementation, these numbers decreased to 0.2% (p < .001) and 1.8% (p = .869) and within-60-days-re-testing decreased to 1.1% (p < .001) and 3.6% (p = .003) in LKH and STV, respectively. Median monthly HbA1c measurements decreased by 15.8% (p < .001) and 21.1% (p = .002) in LKH and STV, respectively. CONCLUSION: Both the educational and the automated 60-day-RTI were proven to be efficient in reducing overall HbA1c measurements, re-testing within 60 days and eFER.


Asunto(s)
Diabetes Mellitus Tipo 2/diagnóstico , Hemoglobina Glucada/análisis , Anciano , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/terapia , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Probabilidad , Estudios Retrospectivos , Procedimientos Innecesarios
11.
Clin Chem Lab Med ; 58(9): 1565-1571, 2020 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-32305953

RESUMEN

Background: Laboratory overutilization is associated with diagnostic error and potential patient risk. We applied a demand management strategy in collaboration with the local Department of Cardiology to reduce the cardiac markers high-sensitive troponin T (hsTropT) and N-terminal pro brain natriuretic peptide (NTproBNP) in laboratory ordering profiles (LOPs). The present study aimed to retrospectively evaluate the implemented strategies. Methods: Strategies included educational measures and evidence-guided, active test de-selection from all cardiology ward LOPs, and/or permanent removal from LOPs. Tests remained available at all times. We evaluated overutilization by reductions in monthly orders, and assessed differences in 30-day all-cause readmission rate and length of patients' hospital stay. Results: Overall, we observed a mean reduction of 66.1% ± 7.6% (n = 277 ± 31) in hsTropT tests. Educational measures effectively reduced NTproBNP orders by 52.8% ± 17.7% (n = 60 ± 20). Permanent removal of tests from LOPs additionally decreased orders to a final extent of 75.8% ± 8.0% (n = 322 ± 31) in NTproBNP tests. The 30-day readmission rate and overall length of hospital stay did not increase. Conclusions: Our results indicate that cardiac markers in routine care are subject to extensive overutilization when used within LOPs. Educational measures are an effective strategy to overcome the overutilization of cardiac markers but may be more effective when combined with the removal of cardiac markers from LOPs.


Asunto(s)
Pruebas Diagnósticas de Rutina/economía , Cardiopatías/sangre , Unidades Hospitalarias , Biomarcadores/sangre , Humanos , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Estudios Retrospectivos , Troponina T
12.
Clin Chim Acta ; 505: 100-107, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32084382

RESUMEN

INTRODUCTION: The appropriate use of laboratory diagnostics is increasingly at stake. The aim of this study was to depict some paradigmatic examples of under- and overutilization, as well as possible solutions across Europe. METHODS: We collected six examples from five European countries where a rise or decline of orders for specific laboratory parameters was observed after organizational changes but without evidence of changes in patient collective characteristics as source of this variation. RESULTS: The collected examples were the following: 1-Germany) Switch from a Brain-Natriuretic-Peptide assay to NT-pro Brain-Natriuretic-Peptide assay, resulting in a 374% increase in these analytics; 2-Spain) Implementation of a gatekeeping strategy in tumor marker diagnostics, resulting in a 15-61% reduction of these diagnostics; 3-Croatia) Stepwise elimination of creatine-kinase-MB assay from the laboratory portfolio; 4-UK) Removal of γ-glutamyl transferase from a "liver function" profile, resulting in 82% reduction of orders; 5-Austria) Implementation of a new device for rapid Influenza-RNA detection, resulting in a 450% increase of Influenza testing; 6-Spain) Insourcing of 1,25-(OH)2-Vitamin D measurements, leading to a 378% increase of these analyses. CONCLUSION: The six paradigmatic examples described in this manuscript show that availability of laboratory resources may considerably catalyze the demand, thus underscoring that inappropriate use of laboratory resources may be commonplace in routine laboratories all across Europe and most probably beyond. They also demonstrate that the application of simple strategies may assist in overcoming this issue. We believe that laboratory specialists need to refocus on the extra-analytical parts of the testing process and engage more in interdisciplinary patient-care.


Asunto(s)
Técnicas de Laboratorio Clínico/estadística & datos numéricos , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Prescripción Inadecuada/estadística & datos numéricos , Biomarcadores de Tumor/análisis , Forma MB de la Creatina-Quinasa/análisis , Europa (Continente) , Humanos , Hidroxicolecalciferoles/análisis , Gripe Humana/sangre , Péptido Natriurético Encefálico/análisis , Fragmentos de Péptidos/análisis , gamma-Glutamiltransferasa/análisis
13.
Clin Chem Lab Med ; 57(12): 1888-1896, 2019 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-31377734

RESUMEN

Background Published evidence on the risk of additive carryover during phlebotomy remains elusive. We aimed to assess potential carryover of citrated and heparinized blood and the relative volume needed to bias clinical chemistry and coagulation tests. Methods We simulated standardized phlebotomies to quantify the risk of carryover of citrate and heparin additives in distilled water, using sodium and lithium as surrogates. We also investigated the effects of contamination of heparinized blood samples with increasing volumes of citrated blood and pure citrate on measurements of sodium, potassium, chloride, magnesium, total and ionized calcium and phosphate. Likewise, we studied the effects of contamination of citrated blood samples with increasing volumes of heparinized blood on heparin (anti-Xa) activity, lithium, activated partial thromboplastin time (APTT), prothrombin time (PT) and thrombin time (TT). We interpreted these results based on measurement deviations beyond analytical, biological and clinical significance. Results Standardized phlebotomy simulations revealed no significant differences in concentration of surrogate markers. Clinically significant alterations were observed after contamination of heparinized blood samples with volumes of citrated blood beyond 5-50 µL for ionized calcium and beyond 100-1000 µL for sodium, chloride and total calcium. Investigations of pure citrate carryover revealed similar results at somewhat lower volumes. Heparinized blood carryover showed clinically significant interference of coagulation testing at volumes beyond 5-100 µL. Conclusions Our results suggest that during a standardized phlebotomy, heparin or citrate contamination is highly unlikely. However, smaller volumes are sufficient to severely alter test results when deviating from phlebotomy guidelines.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Ácido Cítrico/análisis , Heparina/análisis , Anticoagulantes , Coagulación Sanguínea/efectos de los fármacos , Pruebas de Coagulación Sanguínea/métodos , Citratos , Ácido Cítrico/sangre , Contaminación de Equipos/prevención & control , Heparina/sangre , Humanos , Tiempo de Tromboplastina Parcial , Flebotomía/métodos , Flebotomía/normas , Fase Preanalítica/métodos , Tiempo de Protrombina , Tiempo de Trombina
14.
PLoS One ; 14(2): e0212973, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30817774

RESUMEN

BACKGROUND: Marinobufagenin (MBG) is an endogenous cardiotonic steroid (CTS) that inhibits the Na+/K+-ATPase. Human MBG is significantly increased in end-stage renal disease and immunization against MBG attenuates cardiovascular fibrosis in a rat model of uremic cardiomyopathy. Mineralocorticoid antagonists (MRA) block MBG binding sites and decrease proteinuria in chronic kidney disease (CKD) patients. We therefore aimed to investigate the association of MBG and albuminuria, as a marker of renal damage, as well as MBG and decline of glomerular filtration rate (GFR). METHODS: The Graz endocrine causes of hypertension (GECOH) study is a single center study of adults routinely referred for screening of endocrine hypertension. Plasma MBG was measured by an enzyme-linked immunoassay, and in a post-hoc analysis, follow-up creatinine levels were obtained. Patients with proteinuria >3.5g/day at baseline were excluded from further evaluation. RESULTS: We measured MBG concentrations in 40 hypertensive subjects and excluded one patient due to pre-existing proteinuria. Plasma MBG was significantly correlated with albuminuria (Spearman ρ = .357; p = .028) and proteinuria (ρ = .336; p = .039). In linear regression analysis, the association remained significant after adjustment for age, sex, and BMI (ß = .306; p = .036), and for mean systolic blood pressure (ß = .352; p = .034). In follow-up analyses (N = 30), MBG was significantly associated with decline in GFR after adjustment for time-to-follow-up (ß = -.374; p = .042). CONCLUSION: The findings suggest that MBG plasma concentrations were associated with albuminuria as well as decline in kidney function. Whether MBG predicts hard renal endpoints warrants further investigations.


Asunto(s)
Bufanólidos/sangre , Tasa de Filtración Glomerular/fisiología , Hipertensión/sangre , Hipertensión/fisiopatología , Adulto , Anciano , Albuminuria/sangre , Albuminuria/fisiopatología , Animales , Biomarcadores/sangre , Cardiotónicos/sangre , Inhibidores Enzimáticos/sangre , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Proteinuria/sangre , Proteinuria/fisiopatología , Ratas , Insuficiencia Renal Crónica/sangre , Insuficiencia Renal Crónica/fisiopatología
15.
J Transl Med ; 17(1): 432, 2019 12 30.
Artículo en Inglés | MEDLINE | ID: mdl-31888679

RESUMEN

BACKGROUND: Innovative human stromal cell therapeutics require xeno-free culture conditions. Various formulations of human platelet lysate (HPL) are efficient alternatives for fetal bovine serum (FBS). However, a consistent lack of standardized manufacturing protocols and quality criteria hampers comparability of HPL-products. Aim of this study was to compare the biochemical composition of three differential HPL-preparations with FBS and to investigate their impact on stromal cell biology. METHODS: Stromal cells were isolated from bone marrow (BM), white adipose tissue (WAT) and umbilical cord (UC) and cultured in medium supplemented with pooled HPL (pHPL), fibrinogen-depleted serum-converted pHPL (pHPLS), mechanically fibrinogen-depleted pHPL (mcpHPL) and FBS. Biochemical parameters were analyzed in comparison to standard values in whole blood. Distinct growth factors and cytokines were measured by bead-based multiplex technology. Flow cytometry of stromal cell immunophenotype, in vitro differentiation, and mRNA expression analysis of transcription factors SOX2, KLF4, cMYC, OCT4 and NANOG were performed. RESULTS: Biochemical parameters were comparable in all pHPL preparations, but to some extent different to FBS. Total protein, glucose, cholesterol and Na+ were elevated in pHPL preparations, K+ and Fe3+ levels were higher in FBS. Compared to FBS, pHPL-based media significantly enhanced stromal cell propagation. Characteristic immunophenotype and in vitro differentiation potential were maintained in all four culture conditions. The analysis of growth factors and cytokines revealed distinct levels depending on the pre-existence in pHPL, consumption or secretion by the stromal cells. Interestingly, mRNA expression of the transcription and mitotic bookmarking factors cMYC and KLF4 was significantly enhanced in a source dependent manner in stromal cells cultured in pHPL- compared to FBS-supplemented media. SOX2 mRNA expression of all stromal cell types was increased in all pHPL culture conditions. CONCLUSION: All pHPL-supplemented media equally supported proliferation of WAT- and UC-derived stromal cells significantly better than FBS. Mitotic bookmarking factors, known to enable a quick re-entry to the cell cycle, were significantly enhanced in pHPL-expanded cells. Our results support a better characterization and standardization of humanized culture media for stromal cell-based medicinal products.


Asunto(s)
Plaquetas/metabolismo , Diferenciación Celular , Mitosis , Regulación hacia Arriba , Tejido Adiposo Blanco/citología , Células de la Médula Ósea/citología , Diferenciación Celular/genética , Proliferación Celular , Citocinas/metabolismo , Humanos , Inmunofenotipificación , Péptidos y Proteínas de Señalización Intercelular/metabolismo , Factor 4 Similar a Kruppel , Mitosis/genética , ARN Mensajero/genética , ARN Mensajero/metabolismo , Células del Estroma/citología , Células del Estroma/metabolismo , Factores de Transcripción/genética , Factores de Transcripción/metabolismo , Cordón Umbilical/citología , Regulación hacia Arriba/genética
16.
Clin Biochem ; 54: 85-91, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29409798

RESUMEN

BACKGROUND: Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. METHODS: We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. RESULTS: From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. CONCLUSIONS: Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers.


Asunto(s)
Análisis Químico de la Sangre , Hospitales , Uso Excesivo de los Servicios de Salud , Femenino , Humanos , Masculino , Estudios Retrospectivos
17.
Biochem Med (Zagreb) ; 28(1): 010704, 2018 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-29187797

RESUMEN

INTRODUCTION: Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. MATERIALS AND METHODS: We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. RESULTS: High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to < 0.001) and lower bicarbonate values (P = 0.049 to 0.008) in the latter. CONCLUSIONS: Serum and heparin samples may be centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.


Asunto(s)
Recolección de Muestras de Sangre/instrumentación , Química Clínica/métodos , Centrifugación , Química Clínica/instrumentación , Humanos , Compuestos Inorgánicos/sangre , Compuestos Orgánicos/sangre
18.
Biochem Med (Zagreb) ; 27(2): 430-433, 2017 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-28694735

RESUMEN

We report on a preanalytical issue we encountered during routine clinical chemistry analyses, potentially leading to deviated analysis results and believe that it might help other laboratories to overcome similar problems. In a heparin-gel tube we measured an implausible glucose value of 0.06 mmol/L. Re-measurement of the same sample resulted in a glucose value of 5.4 mmol/L. After excluding an analytical error, we inspected the sample closer and found a white material as well as fatty droplets floating on the surface of the plasma tube. Evaluation of these structures revealed that the white particulate matter (WPM) consisted of fibrinogen, platelets and leukocytes and the fatty droplets most probably originated from the separator gel. We concluded that these structures formed a temporary clot in the instruments pipetting needle thereby altering the sampling volume and subsequently the measured glucose value. The formation of WPM might be attributable to high speed centrifugation, high cholesterol levels, the gel formulation or a combination of several issues such as temperature, heparin concentration, pH and patient-specific factors. The gel droplets were most probably caused by an aberrant gel formulation in combination with an improper storage of the empty tubes on the wards prior to phlebotomy. After adding an additional instrument cleansing cycle and changing to another batch of heparin tubes the problems could be significantly reduced.


Asunto(s)
Análisis Químico de la Sangre/normas , Glucemia/análisis , Recolección de Muestras de Sangre/normas , Heparina/química , Análisis Químico de la Sangre/métodos , Plaquetas/química , Recolección de Muestras de Sangre/instrumentación , Recolección de Muestras de Sangre/métodos , Colesterol/química , Grasas/química , Fibrinógeno/química , Geles/química , Humanos , Concentración de Iones de Hidrógeno , Leucocitos/química , Material Particulado/química , Reproducibilidad de los Resultados , Trombosis
20.
Clin Chem Lab Med ; 55(8): 1109-1111, 2017 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-28207409

RESUMEN

Preanalytically altered test results are a challenge every laboratory has to face. The release of such results may be to the harm of the patient by triggering wrong clinical decision making in monitoring or treatment. On the other hand, their deletion also might be to the harm of the patient by delaying the time to decision making as the exact value sometimes is not even necessary but rather an answer to the question "Is it raised or lowered". Based on this dilemma and forced to produce laboratory values without any clinical information on the respective patient, laboratories have developed their own preferred way on how to deal with preanalytically altered test results. Some release the value with a comment, some reject the value with or without a comment and others again provide only general information about the hemolytic sample. To date there is no guideline or standardization to this postanalytical topic. Therefore, with this opinion paper, we want to start the scientific discussion on this important issue by providing one possible method to overcome the lack of clinical information which the laboratory would need to correctly decide whether or not to release an altered test result. We suggest providing the clinician with all the information on the hemolytic sample and its impact on the respective parameter needed to make his/her own decision on the usage of the respective test result. We believe that reporting a preanalytically altered laboratory value including a respective comment is preferable to not reporting it.


Asunto(s)
Técnicas de Laboratorio Clínico , Toma de Decisiones , Hemólisis , Errores Médicos , Proyectos de Investigación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...